Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 809
Filtrar
1.
Virchows Arch ; 484(1): 31-36, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37017774

RESUMEN

Synoptic reporting increases completeness and standardization of surgical pathology reports and thereby contributes to an increased quality of clinical cancer care. Nevertheless, its widespread practical implementation remains a challenge, which is in part related to the effort required for setup and maintenance of database structures. This prompted us to assess the effect of a simple template-based, database-free system for synoptic reporting on completeness of surgical pathology reports. For this purpose, we analyzed 200 synoptic reports (100 colon and 100 lung cancer resections each) for completeness as required by the pertinent College of American Pathologists (CAP) protocols and compared these to a control dataset of 200 narrative reports. Introduction of template-based synoptic reporting resulted in improved completeness (98% of mandatory data elements) as compared to narrative reports (77%). Narrative reports showed a high degree of completeness for data elements covered by previously existing dictation templates. In conclusion, template-based synoptic reporting without underlying database structure can be a useful transitory phase in the implementation of synoptic reporting. It can result in a similar degree of completeness as reported in the literature for database solutions and provides other benefits of synoptic reporting while facilitating its implementation.


Asunto(s)
Patología Quirúrgica , Humanos , Patología Quirúrgica/métodos , Informe de Investigación , Bases de Datos Factuales
2.
Arch Pathol Lab Med ; 148(3): 345-352, 2024 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-37226827

RESUMEN

CONTEXT.­: Digital pathology using whole slide images has been recently approved to support primary diagnosis in clinical surgical pathology practices. Here we describe a novel imaging method, fluorescence-imitating brightfield imaging, that can capture the surface of fresh tissue without requiring prior fixation, paraffin embedding, tissue sectioning, or staining. OBJECTIVE.­: To compare the ability of pathologists to evaluate direct-to-digital images with standard pathology preparations. DESIGN.­: One hundred surgical pathology samples were obtained. Samples were first digitally imaged, then processed for standard histologic examination on 4-µm hematoxylin-eosin-stained sections and digitally scanned. The resulting digital images from both digital and standard scan sets were viewed by each of 4 reading pathologists. The data set consisted of 100 reference diagnoses and 800 study pathologist reads. Each study read was compared to the reference diagnosis, and also compared to that reader's diagnosis across both modalities. RESULTS.­: The overall agreement rate, across 800 reads, was 97.9%. This consisted of 400 digital reads at 97.0% versus reference and 400 standard reads versus reference at 98.8%. Minor discordances (defined as alternative diagnoses without clinical treatment or outcome implications) were 6.1% overall, 7.2% for digital, and 5.0% for standard. CONCLUSIONS.­: Pathologists can provide accurate diagnoses from fluorescence-imitating brightfield imaging slide-free images. Concordance and discordance rates are similar to published rates for comparisons of whole slide imaging to standard light microscopy of glass slides for primary diagnosis. It may be possible, therefore, to develop a slide-free, nondestructive approach for primary pathology diagnosis.


Asunto(s)
Patología Quirúrgica , Humanos , Hematoxilina , Eosina Amarillenta-(YS) , Patología Quirúrgica/métodos , Adhesión en Parafina , Microscopía/métodos , Formaldehído
3.
Arch Pathol Lab Med ; 148(1): 68-73, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-36920004

RESUMEN

CONTEXT.­: Intraoperative diagnosis by frozen section is a mainstay of surgical pathology practice, providing immediate feedback to the surgical team. Despite good accuracy with modern methods, access to intraoperative surgical pathology with an appropriate turnaround time (TAT) has been a limiting factor for small or remote surgical centers, with negative impacts on cost and patient care. Telepathology offers immediate expert anatomic pathology consultation to sites without an in-house or subspecialized pathologist. OBJECTIVE.­: To assess the utility of live telepathology in frozen section practice. DESIGN.­: Frozen section diagnoses by telemicroscopy from 2 tertiary care centers with a combined 3 satellite hospitals were queried for anatomic site, TAT per block, pathologist, and concordance with paraffin diagnosis. TAT and concordance were compared to glass diagnoses in the same period. RESULTS.­: For 748 intraoperative diagnoses by telemicroscopy, 694 had TATs with a mean of 18 minutes 56 seconds ± 8 minutes 45 seconds, which was slower than on glass (14 minutes 25 seconds ± 7 minutes 8 seconds, P < .001). Twenty-two (2.89% of available) were discordant, which was not significantly different from the on-glass rate (P = .44) or categorical distribution (P = .31). Two cases (0.27%) had technical failures. CONCLUSIONS.­: Although in-person diagnoses were statistically faster, the great majority of telemicroscopic diagnoses were returned in less than 20 minutes. This remained true through numerous pathologists, pathology assistants and/or technicians, different hospitals, and during a combined 6 years. The concentration of discordant diagnoses among relatively few pathologists suggests individual comfort with telepathology and/or frozen section diagnosis. In rare cases, technical issues prevented telemicroscopic diagnosis. Overall, this justifies continued use and expansion of telemicroscopic services in primary intraoperative diagnoses.


Asunto(s)
Patología Quirúrgica , Telepatología , Humanos , Secciones por Congelación/métodos , Telepatología/métodos , Patología Quirúrgica/métodos , Centros de Atención Terciaria , Tomografía Computarizada por Rayos X
4.
Int J Surg Pathol ; 32(3): 433-448, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37437093

RESUMEN

Background. Whole slide imaging (WSI) represents a paradigm shift in pathology, serving as a necessary first step for a wide array of digital tools to enter the field. It utilizes virtual microscopy wherein glass slides are converted into digital slides and are viewed by pathologists by automated image analysis. Its impact on pathology workflow, reproducibility, dissemination of educational material, expansion of service to underprivileged areas, and institutional collaboration exemplifies a significant innovative movement. The recent US Food and Drug Administration approval to WSI for its use in primary surgical pathology diagnosis has opened opportunities for wider application of this technology in routine practice. Main Text. The ongoing technological advances in digital scanners, image visualization methods, and the integration of artificial intelligence-derived algorithms with these systems provide avenues to exploit its applications. Its benefits are innumerable such as ease of access through the internet, avoidance of physical storage space, and no risk of deterioration of staining quality or breakage of slides to name a few. Although the benefits of WSI to pathology practices are many, the complexities of implementation remain an obstacle to widespread adoption. Some barriers including the high cost, technical glitches, and most importantly professional hesitation to adopt a new technology have hindered its use in routine pathology. Conclusions. In this review, we summarize the technical aspects of WSI, its applications in diagnostic pathology, training, and research along with future perspectives. It also highlights improved understanding of the current challenges to implementation, as well as the benefits and successes of the technology. WSI provides a golden opportunity for pathologists to guide its evolution, standardization, and implementation to better acquaint them with the key aspects of this technology and its judicial use. Also, implementation of routine digital pathology is an extra step requiring resources which (currently) does not usually result increased efficiency or payment.


Asunto(s)
Inteligencia Artificial , Patología Quirúrgica , Humanos , Reproducibilidad de los Resultados , Procesamiento de Imagen Asistido por Computador/métodos , Microscopía/métodos , Patología Quirúrgica/métodos
5.
Pathol Res Pract ; 251: 154843, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37826873

RESUMEN

BACKGROUND: The establishment of minimum standards for display selection for the whole slide image (WSI) interpretation has not been fully defined. Recently, pathologists have increasingly preferred using remote displays for clinical diagnostics. Our study aims to assess and compare the performance of three fixed work displays and one remote personal display in accurately identifying ten selected pathologic features integrated into WSIs. DESIGN: Hematoxylin and eosin-stained glass slides were digitized using Philips scanners. Seven practicing pathologists and three residents reviewed ninety WSIs to identify ten pathologic features using the LG, Dell, and Samsung and an optional consumer-grade display. Ten pathologic features included eosinophils, neutrophils, plasma cells, granulomas, necrosis, mucin, hemosiderin, crystals, nucleoli, and mitoses. RESULTS: The accuracy of the identification of ten features on different types of displays did not significantly differ among the three types of "fixed" workplace displays. The highest accuracy was observed for the identification of neutrophils, eosinophils, plasma cells, granuloma, and mucin. On the other hand, a lower accuracy was observed for the identification of crystals, mitoses, necrosis, hemosiderin, and nucleoli. Participant pathologists and residents preferred the use of larger displays (>30″) with a higher pixel count, resolution, and luminance. CONCLUSION: Most features can be identified using any display. However, certain features posed more challenges across the three fixed display types. Furthermore, the use of a remote personal consumer-grade display chosen according to the pathologists' preference showed similar feature identification accuracy. Several factors of display characteristics seemed to influence pathologists' display preferences such as the display size, color, contrast ratio, pixel count, and luminance calibration. This study supports the use of standard "unlocked" vendor-agnostic displays for clinical digital pathology workflow rather than purchasing "locked" and more expensive displays that are part of a digital pathology system.


Asunto(s)
Microscopía , Patología Quirúrgica , Humanos , Microscopía/métodos , Patología Quirúrgica/métodos , Hemosiderina , Mucinas , Necrosis
6.
Mod Pathol ; 36(11): 100297, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37544362

RESUMEN

As digital pathology replaces conventional glass slide microscopy as a means of reporting cellular pathology samples, the annotation of digital pathology whole slide images is rapidly becoming part of a pathologist's regular practice. Currently, there is no recognizable organization of these annotations, and as a result, pathologists adopt an arbitrary approach to defining regions of interest, leading to irregularity and inconsistency and limiting the downstream efficient use of this valuable effort. In this study, we propose a Standardized Annotation Reporting Style for digital whole slide images. We formed a list of 167 commonly annotated entities (under 12 specialty subcategories) based on review of Royal College of Pathologists and College of American Pathologists documents, feedback from reporting pathologists in our NHS department, and experience in developing annotation dictionaries for PathLAKE research projects. Each entity was assigned a suitable annotation shape, SNOMED CT (SNOMED International) code, and unique color. Additionally, as an example of how the approach could be expanded to specific tumor types, all lung tumors in the fifth World Health Organization of thoracic tumors 2021 were included. The proposed standardization of annotations increases their utility, making them identifiable at low power and searchable across and between cases. This would aid pathologists reporting and reviewing cases and enable annotations to be used for research. This structured approach could serve as the basis for an industry standard and be easily adopted to ensure maximum functionality and efficiency in the use of annotations made during routine clinical examination of digital slides.


Asunto(s)
Patología Clínica , Patología Quirúrgica , Neoplasias Torácicas , Humanos , Patología Clínica/métodos , Patología Quirúrgica/métodos , Patólogos , Microscopía/métodos
7.
Diagn Pathol ; 18(1): 55, 2023 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-37106381

RESUMEN

BACKGROUND: The concept of critical value is not evident in surgical pathology, and there is no established protocol for determining, reporting, and documenting these results. MATERIALS AND METHODS: A questionnaire was designed regarding critical value in surgical pathology, and all pathologists and some clinicians from five laboratories were asked to participate through an invitation link. The most important items were selected, and all pathologists were instructed to follow a standard operating procedure to deal with critical results for a year. RESULTS: A total of 43 pathologists and 44 non-pathologists participated in the study. Some critical or unexpected items were selected. Most participants agreed that the optimal time to announce critical reports is within 24 h of establishing the final diagnosis, and a phone call was the most dependable communication option. In addition, the most qualified recipients were the attending physicians. Therefore, a written policy was implemented for a year. One hundred seventy-seven critical or unexpected cases (0.5%) were detected. Mucormycosis and cytomegalovirus (CMV) were the most frequent critical cases. CONCLUSION: There are no set criteria for critical items or the reporting process in surgical pathology. It is possible to establish more uniform norms for reporting these cases by boosting pertinent research efforts and recruiting more pathologists and physicians. Additionally, it is advised that each medical facility compile its own unique critical or unexpected diagnosis list.


Asunto(s)
Laboratorios , Patología Quirúrgica , Humanos , Patología Quirúrgica/métodos , Patólogos
8.
Arch Pathol Lab Med ; 147(3): 359-367, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-35802938

RESUMEN

CONTEXT.­: Stanford Pathology began stepwise subspecialty implementation of whole slide imaging (WSI) in 2018 soon after the first US Food and Drug Administration approval. In 2020, during the COVID-19 pandemic, the Centers for Medicare & Medicaid Services waived the requirement for pathologists to perform diagnostic tests in Clinical Laboratory Improvement Amendments (CLIA)-licensed facilities. This encouraged rapid implementation of WSI across all surgical pathology subspecialties. OBJECTIVE.­: To present our experience with validation and implementation of WSI at a large academic medical center encompassing a caseload of more than 50 000 cases per year. DESIGN.­: Validation was performed independently for 3 subspecialty services with a diagnostic concordance threshold above 95%. Analysis of user experience, staffing, infrastructure, and information technology was performed after department-wide expansion. RESULTS.­: Diagnostic concordance was achieved in 96% of neuropathology cases, 100% of gynecologic pathology cases, and 98% of immunohistochemistry cases. After full implementation, 8 high-capacity scanners were operational, with whole slide images generated on greater than 2000 slides per weekday, accounting for approximately 80% of histologic slides at Stanford Medicine. Multiple modifications in workflow and information technology were needed to improve performance. Within months of full implementation, most attending pathologists and trainees had adopted WSI for primary diagnosis. CONCLUSIONS.­: WSI across all surgical subspecialities is achievable at scale at an academic medical center; however, adoption required flexibility to adjust workflows and develop tailored solutions. WSI at scale supported the health and safety of medical staff while facilitating high-quality patient care and education during COVID-19 restrictions.


Asunto(s)
COVID-19 , Patología Quirúrgica , Anciano , Estados Unidos , Humanos , Femenino , Patología Quirúrgica/métodos , Interpretación de Imagen Asistida por Computador/métodos , Pandemias/prevención & control , Microscopía/métodos , Medicare , Prueba de COVID-19
9.
Int J Surg Pathol ; 31(6): 949-956, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35971290

RESUMEN

Background. Frozen sections (FS) are common in neurosurgery to address varied clinical concerns. Artifacts in central nervous system (CNS) FS can be severe and affect or hinder interpretation. We performed a case-control study using a semiquantitative scale: the Histologic Preservation Score (HPS), and a quantitative scale: the Ice Crystal Vacuolization Score (ICVS), to compare the histologic quality yielded by snap- versus cryostat freezing techniques. Material and Methods. All specimens were sectioned in 2 halves, one half was used for FS and the other for permanent evaluation. HPS assigns a distortion score to the FS sample using the non-frozen half as the comparator: 1 = minimal, 2 = slight, 3 = moderate, 4 & 5 = severe. The ICVS is the average size in µm of the 5 largest vacuoles/0.05 mm2, evaluated on digitized slides. Results. 86 CNS-FS were collected: 22 snap- and 64 cryostat-FS. Significant differences in HPS: 2.28 versus 2.84 (p <0.05) and ICVS 7.47 versus 14.56 (p < 0.001) were obtained for snap- versus cryostat-FS, respectively. HPS and ICVS showed a strong correlation: R2 = 0.63, p < 0.0001. Histologic distortion was worse for neuroglial than mesenchymal tissue by both methods; however, a significant difference was only observed in cryostat-FS: HPS: 3.23 versus 2.33, p < 0.001; ICVS: 16.86 µm versus 10.26 µm, p < 0.001. Conclusion. Snap-FS yields better histologic quality than cryostat-FS for CNS-FS, and the difference is more pronounced in neuroglial samples. HPS and ICVS correlate strongly, indicating that the histologic quality is inversely proportional to water-crystallization. These results may apply to other areas of surgical pathology.


Asunto(s)
Procedimientos Neuroquirúrgicos , Patología Quirúrgica , Humanos , Estudios de Casos y Controles , Secciones por Congelación , Derivación y Consulta , Patología Quirúrgica/métodos
10.
Am J Clin Pathol ; 158(6): 692-701, 2022 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-36197800

RESUMEN

OBJECTIVES: Monitoring of frozen section diagnostic performance provides an important quality improvement measure. METHODS: Surgical specimens involving a frozen section diagnosis over a 3-year period were retrospectively reviewed. Glass slides were reviewed on cases with discordance. Discordance and deferral rates were calculated. RESULTS: Of 3,675 frozen section diagnoses included, 96 (2.7%) were discordant with the final diagnosis. Additionally, 114 frozen section diagnoses (3.1%) were deferred. The organ-specific discordance rates were lowest in breast and genitourinary specimens and highest for pancreas, lymph node, and gynecologic specimens. Deferral rates were highest in musculoskeletal, breast, and hepatobiliary cases and lowest in thyroid, parathyroid, and neuropathology cases. Discordance was explained by block-sampling error (45%), specimen-sampling error (27%), or interpretation error (27%). Discordant frozen section diagnoses from gynecologic specimens were responsible for 81% of specimen-sampling errors; frozen section diagnoses of lymph nodes, head and neck, and pancreas were responsible for 54% of interpretation errors; 51% of block-sampling errors involved lymph node evaluation for metastatic carcinoma. CONCLUSIONS: Careful gross evaluation and microscopic examination of multiple levels should minimize specimen-sampling error and block-sampling error, respectively. Periodic review of accuracy and deferral rates may help reduce errors and improve the overall performance of this essential procedure.


Asunto(s)
Secciones por Congelación , Patología Quirúrgica , Femenino , Humanos , Secciones por Congelación/métodos , Patología Quirúrgica/métodos , Periodo Intraoperatorio , Estudios Retrospectivos , Errores Diagnósticos/prevención & control
11.
Am J Clin Pathol ; 158(5): 655-663, 2022 11 03.
Artículo en Inglés | MEDLINE | ID: mdl-36208148

RESUMEN

OBJECTIVES: To determine outcomes following relocation of frozen section services (FSS) and the implementation of a dedicated gastrointestinal frozen service. METHODS: We reviewed our FSS 6 months prior to and following FSS relocation. Satisfaction surveys were sent to surgeons and pathologists. Survey feedback resulted in a pilot of gastrointestinal subspecialist frozen section coverage. RESULTS: There were 1,607 and 1,472 specimens from 667 and 602 patients pre- and post-FSS relocation, respectively. There was a decline in median specimen delivery time to pathology (12 vs 10 minutes, P < .001) and an increase in median time from receipt in pathology to intraoperative diagnosis (20 vs 22 minutes, P = .008) in cases with intrapathology consultation but no change without consultation (median, 19 minutes). Intrapathology consultation decreased from 19.7% (317/1,607) to 11.5% (169/1,472) (P < .001). Discordance rates between frozen section and permanent section remained low and similar (2.0% [33/1,607] vs 2.7% [40/1,472], P = .24). There was no significant change in discordance with dedicated gastrointestinal subspecialty frozen section interpretation. CONCLUSIONS: Relocation of FSS and dedicated subspecialty interpretation may improve surgeon satisfaction but can also create workflow challenges. Pathology departments need to achieve a balance between satisfaction and adequacy to establish best frozen section coverage models.


Asunto(s)
Secciones por Congelación , Patología Quirúrgica , Humanos , Secciones por Congelación/métodos , Patología Quirúrgica/métodos , Derivación y Consulta , Hospitales , Errores Diagnósticos
12.
Virchows Arch ; 481(2): 295-305, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35672584

RESUMEN

Consultation by subspecialty experts is the most common mode of rendering diagnosis in challenging cases in pathological practice. Our study aimed to highlight the diagnostic benefits of whole-slide image (WSI)-based remote consultation. We obtained diagnostically challenging cases from two institutions from the years 2010 and 2013, with histological diagnoses that contained keywords "probable," "suggestive," "suspicious," "inconclusive," and "uncertain." A total of 270 cases were selected for remote consultation using WSIs scanned at 40 × . The consultation process consisted of three rounds: the first and second rounds each with 12 subspecialty experts and the third round with six multi-expertise senior pathologists. The first consultation yielded 44% concordance, and a change in diagnosis occurred in 56% of cases. The most frequent change was from inconclusive to definite diagnosis (30%), followed by minor discordance (14%), and major discordance (12%). Out of the 70 cases which reached the second round, 31 cases showed discrepancy between the two consultants. For these 31 cases, a consensus diagnosis was provided by six multi-expertise senior pathologists. Combining all WSI-based consultation rounds, the original inconclusive diagnosis was changed in 140 (52%) out of 266 cases. Among these cases, 80 cases (30%) upgraded the inconclusive diagnosis to a definite diagnosis, and 60 cases (22%) changed the diagnosis with major or minor discordance, accounting for 28 cases (10%) and 32 cases (12%), respectively. We observed significant improvement in the pathological diagnosis of difficult cases by remote consultation using WSIs, which can further assist in patient healthcare. A post-study survey highlighted various benefits of WSI-based consults.


Asunto(s)
Patología Quirúrgica , Consulta Remota , Telepatología , Humanos , Microscopía/métodos , Patología Quirúrgica/métodos , Consulta Remota/métodos , Telepatología/métodos
13.
Am J Clin Pathol ; 157(5): 767-773, 2022 05 04.
Artículo en Inglés | MEDLINE | ID: mdl-35512255

RESUMEN

OBJECTIVES: To demonstrate how the educational presentation and targeted review of cases with discrepant interpretive findings between pathologists can raise awareness for specific diagnostic errors through identification of common overarching patterns of error in interpretive pathology. METHODS: We performed a review of 147 surgical pathology and cytopathology cases of discordances from 23 PowerPoint presentations presented between 2010 and 2017. Pathologists and pathology residents, blinded from the official interpretations, were presented each case and surveyed for their own diagnostic assessments. Survey results were compared with the final/correct interpretations of the signing pathologists. RESULTS: Of the 134 cases with available survey results, there were 87 (64.9%) for which most survey respondents proposed a diagnostic interpretation concordant with the final/correct diagnosis. There were 37 (27.6%) cases for which most survey responses were either wholly or partially discordant with the final/correct diagnosis. For 10 (7.5%) cases, there were equal numbers of concordant and discordant survey responses. CONCLUSIONS: Our analyses of the cases with frequent erroneous diagnoses reveal common patterns of error that are widely applicable and outline specific error-prone interpretive tendencies. Greater awareness for these tendencies, highlighted by presentation of discordant cases, can improve the quality of diagnostic pathology services.


Asunto(s)
Patología Quirúrgica , Errores Diagnósticos , Humanos , Patología Quirúrgica/métodos
14.
Pathobiology ; 89(5): 324-333, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35443240

RESUMEN

Immunohistochemistry techniques have been incorporated into surgical pathology for nearly a half-century and have since become intimately intertwined with its practice. In the realm of breast pathology, immunohistochemistry serves several purposes, including providing crucial prognostic and predictive data. Among its other applications, assessment of stromal invasion and establishment of mammary origin are crucial from a diagnostic standpoint. In these regards, sole reliance on immunohistochemistry may lead to misdiagnosis. In this review, we highlight pitfalls of immunohistochemistry commonly encountered in the practice of breast pathology and emphasize the importance of careful histopathological evaluation.


Asunto(s)
Neoplasias de la Mama , Patología Quirúrgica , Biomarcadores de Tumor , Mama , Neoplasias de la Mama/diagnóstico , Femenino , Humanos , Inmunohistoquímica , Patología Quirúrgica/métodos
15.
Mod Pathol ; 35(3): 319-325, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34628480

RESUMEN

Optical imaging modalities are emerging as digital microscopy tools for tissue examination. The investigation of these techniques for potential applications in anatomic pathology practice has focused primarily on surgical pathology and has not included cytopathological specimens. We evaluated the feasibility of using digital confocal microscopy (CM) to examine cytopathological specimens. Smears and cell suspensions collected in RPMI solution were prepared from tissue scrapes obtained from surgical resections of breast, lung, liver, and kidney. Air-dried smears and cell pellets obtained from centrifugation of the cell suspensions were stained with 0.6 mM acridine orange and imaged with a CM platform. After completion of imaging, the smears were stained with Diff-Quik (DQ), and cell pellets were routinely processed, embedded in paraffin wax, cut, and stained with hematoxylin and eosin (H&E). We evaluated the mean time to acquire digital CM images; quality of images based on the extent of tissue recognition (0%, grade 0; 1-19%, grade 1; 20-50%, grade 2; >50%, grade 3); comparison of images with DQ- and H&E-stained specimens; and ability to make specific diagnoses. We imaged 91 smears and 52 cell pellets and acquired digital CM images within 2-3 min, with 92% and 88% of images, respectively, from smears and cell pellets showing grade 3 quality. On the basis of CM images, 8 smears (9%) and 7 cell pellets (14%) were categorized as benign, and 83 (91%) and 45 (88%), respectively, as malignant. Specific diagnoses were made by using digital CM images of smears and cell pellets that matched accurately with corresponding DQ- and H&E-stained preparations. The results of our first feasibility study clearly indicated the utility of CM as a next-generation digital microscopy tool for evaluating cytology specimens. Prospective clinical studies are warranted for validating our findings for potential incorporation into cytopathological clinical practice.


Asunto(s)
Patología Quirúrgica , Estudios de Factibilidad , Hematoxilina , Humanos , Microscopía Confocal/métodos , Patología Quirúrgica/métodos , Estudios Prospectivos
16.
Clin Breast Cancer ; 22(2): e214-e223, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34384695

RESUMEN

OBJECTIVE: This study evaluates breast MRI response of ER/PR+ HER2- breast tumors to pre-operative SABR with pathologic response correlation. METHODS: Women enrolled in a phase 2 single institution trial of SABR for ER/PR+ HER2- breast cancer were retrospectively evaluated for radiologic-pathologic correlation of tumor response. These patients underwent baseline breast MRI, SABR (28.5 Gy in 3 fractions), follow-up MRI 5 to 6 weeks post-SABR, and lumpectomy. Tumor size and BI-RADS descriptors on pre and post-SABR breast MRIs were compared to determine correlation with surgical specimen % tumor cellularity (%TC). Reported MRI tumor dimensions were used to calculate percent cubic volume remaining (%VR). Partial MRI response was defined as a BI-RADs descriptor change or %VR ≤ 70%, while partial pathologic response (pPR) was defined as %TC ≤ 70%. RESULTS: Nineteen patients completed the trial, and %TC ranged 10% to 80%. For BI-RADS descriptor analysis, 12 of 19 (63%) showed change in lesion or kinetic enhancement descriptors post-SABR. This was associated with lower %TC (29% vs. 47%, P = .042). BI-RADS descriptor change analysis also demonstrated high PPV (100%) and specificity (100%) for predicting pPR to treatment (sensitivity 71%, accuracy 74%), but low NPV (29%). MRI %VR demonstrated strong linear correlation with %TC (R = 0.70, P < .001, Pearson's Correlation) and high accuracy (89%) for predicting pPR (sensitivity 88%, specificity 100%, PPV 100%, and NPV 50%). CONCLUSION: Evaluating breast cancer response on MRI using %VR after pre-operative SABR treatment can help identify patients benefiting the most from neoadjuvant radiation treatment of their ER/PR+ HER2- tumors, a group in which pCR to neoadjuvant therapy is rare.


Asunto(s)
Neoplasias de la Mama/metabolismo , Neoplasias de la Mama/radioterapia , Patología Quirúrgica/métodos , Radioterapia de Intensidad Modulada/métodos , Receptor ErbB-2/metabolismo , Receptores de Estrógenos/metabolismo , Adulto , Anciano , Neoplasias de la Mama/patología , Femenino , Estudios de Seguimiento , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Estudios Retrospectivos
17.
Prostate ; 82(3): 345-351, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34878188

RESUMEN

BACKGROUND: To validate the importance of recently established adverse histopathology features (cribriform pattern and intraductal carcinoma) as contra-indication for deferred treatment of Gleason score 7 (3 + 4) (grade group [GG] 2) prostate cancer, we investigated their frequency in GG2 radical prostatectomies with syn- or metachronous metastatic disease. METHODS: GG2 prostatectomy specimens of patients with concomitant lymph node metastasis or distant metastasis at follow-up were identified in a clinical database of a tertiary care center and their pathology was reviewed for pathological stage, lymphovascular invasion, Gleason grade 4 subpatterns, presence of tertiary grade 5, and ductal adenocarcinoma histology. A control group of 99 GG2 prostatectomy specimens who had no metastatic disease (controls) was reviewed for the same adverse pathological features. RESULTS: Of 1860 GG2 prostatectomy specimens (operated between 2002 and 2020), 45 (2.4%) had concurrent regional lymph node metastases or distant metastases at follow-up. Pathological stage distribution of cases and controls was 24% and 79% pT2, 42% and 15% pT3a, 33% and 6.1% pT3b -T4, respectively (p < 0.001). Eleven of 45 cases (24%) had ≤10% Gleason grade 4 component. Cribriform pattern or intraductal carcinoma was present in 84% of cases versus 34% of controls (p < 0.001), tertiary grade 5 in 16% of cases versus 5% controls (p = 0.05) and ductal adenocarcinoma in 16% of cases versus 2% of controls (p = 0.004). Among the seven cases without cribriform or intraductal carcinoma, two displayed ductal adenocarcinoma features. CONCLUSIONS: Well-established unfavorable histopathologic features (intraductal and cribriform pattern carcinoma, ductal adenocarcinoma) are represented in about 90% of GG2 prostate cancers with local or distant metastatic disease and are much less common (38%) in those without metastatic disease. Strikingly, about 25% of GG2 prostatectomy cases with metastatic disease had an organ-confined disease and/or a small percentage of Gleason grade 4 pattern. This further emphasizes the relative importance of these adverse histopathological features (cribriform, intraductal, and ductal adenocarcinoma) rather than percentage Gleason grade 4 as contra-indicator of deferred treatment for patients with GG2 prostate cancer.


Asunto(s)
Adenocarcinoma , Próstata/patología , Prostatectomía , Neoplasias de la Próstata , Adenocarcinoma/epidemiología , Adenocarcinoma/patología , Anciano , Canadá/epidemiología , Carcinoma Intraductal no Infiltrante/epidemiología , Carcinoma Intraductal no Infiltrante/patología , Estudios de Casos y Controles , Humanos , Metástasis Linfática/patología , Masculino , Persona de Mediana Edad , Clasificación del Tumor , Invasividad Neoplásica , Metástasis de la Neoplasia/patología , Estadificación de Neoplasias , Neoplasias Primarias Secundarias/epidemiología , Neoplasias Primarias Secundarias/patología , Patología Quirúrgica/métodos , Patología Quirúrgica/estadística & datos numéricos , Prevalencia , Prostatectomía/métodos , Prostatectomía/estadística & datos numéricos , Neoplasias de la Próstata/epidemiología , Neoplasias de la Próstata/patología , Neoplasias de la Próstata/cirugía
18.
Mod Pathol ; 35(1): 52-59, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34518629

RESUMEN

Progression in digital pathology has yielded new opportunities for a remote work environment. We evaluated the utility of digital review of breast cancer immunohistochemical prognostic markers (IHC) using whole slide images (WSI) from formalin fixed paraffin embedded (FFPE) cytology cell block specimens (CB) using three different scanners.CB from 20 patients with breast cancer diagnosis and available IHC were included. Glass slides including 20 Hematoxylin and eosin (H&E), 20 Estrogen Receptor (ER), 20 Progesterone Receptor (PR), 16 Androgen Receptor (AR), and 20 Human Epidermal Growth Factor Receptor 2 (HER2) were scanned on 3 different scanners. Four breast pathologists reviewed the WSI and recorded their semi-quantitative scoring for each marker. Kappa concordance was defined as complete agreement between glass/digital pairs. Discordances between microscopic and digital reads were classified as a major when a clinically relevant change was seen. Minor discordances were defined as differences in scoring percentages/staining pattern that would not have resulted in a clinical implication. Scanner precision was tabulated according to the success rate of each scan on all three scanners.In total, we had 228 paired glass/digital IHC reads on all 3 scanners. There was strong concordance kappa ≥0.85 for all pathologists when comparing paired microscopic/digital reads. Strong concordance (kappa ≥0.86) was also seen when comparing reads between scanners.Twenty-three percent of the WSI required rescanning due to barcode detection failures, 14% due to tissue detection failures, and 2% due to focus issues. Scanner 1 had the best average precision of 92%. HER2 IHC had the lowest intra-scanner precision (64%) among all stains.This study is the first to address the utility of WSI in breast cancer IHC in CB and to validate its reporting using 3 different scanners. Digital images are reliable for breast IHC assessment in CB and offer similar reproducibility to microscope reads.


Asunto(s)
Biomarcadores de Tumor/análisis , Neoplasias de la Mama/diagnóstico , Patología Quirúrgica/métodos , Neoplasias de la Mama/patología , Estudios de Cohortes , Femenino , Humanos , Inmunohistoquímica , Patología Quirúrgica/instrumentación , Pronóstico , Distribución Aleatoria , Receptor ErbB-2/análisis , Receptores Androgénicos/análisis , Receptores de Estrógenos/análisis , Receptores de Progesterona/análisis
19.
Diagn Pathol ; 16(1): 42, 2021 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-33975608

RESUMEN

BACKGROUND: Effective workflow management in a diagnostic pathology laboratory is critical to achieve rapid turnover while maintaining high quality. Fluorescence in situ hybridization analysis (FISH) is the preferred technique for detecting single chromosomal aberrations in diagnostic surgical pathology. MATERIAL AND METHODS: FISH analysis applying a rapid hybridization protocol and using an automated whole-slide fluorescence scanning device (3DHISTECH, Sysmex, Switzerland) were implemented in our workflow. By analyzing 42 diagnostic cases, effects of two different scanning profiles on scanning time, and device memory usage were investigated. Manual signal counting (CaseViewer) and software based signal counting (FISHQuant) were compared. RESULTS: The two scanning profiles, both including a Z-stack function, differed in their exposure time and digital gain. The "low profile" setting (LP) resulted in a significantly shorter scanning time and lower storage volume compared to the "high profile" (HP) setting, making the LP ideal for routine applications. Both signal counting methods (manual versus software based) provided similar cut-offs on a test-cohort of 13 samples. CONCLUSION: Scanning FISH slides provides good picture quality, reduces the analysis time and allows easy picture archiving and facilitates remote diagnostics, allowing an effective workflow.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Hibridación Fluorescente in Situ/métodos , Patología Quirúrgica/métodos , Flujo de Trabajo , Humanos
20.
Mod Pathol ; 34(8): 1588-1595, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33782551

RESUMEN

Prostate cancer is a leading cause of morbidity and mortality for adult males in the US. The diagnosis of prostate carcinoma is usually made on prostate core needle biopsies obtained through a transrectal approach. These biopsies may account for a significant portion of the pathologists' workload, yet variability in the experience and expertise, as well as fatigue of the pathologist may adversely affect the reliability of cancer detection. Machine-learning algorithms are increasingly being developed as tools to aid and improve diagnostic accuracy in anatomic pathology. The Paige Prostate AI-based digital diagnostic is one such tool trained on the digital slide archive of New York's Memorial Sloan Kettering Cancer Center (MSKCC) that categorizes a prostate biopsy whole-slide image as either "Suspicious" or "Not Suspicious" for prostatic adenocarcinoma. To evaluate the performance of this program on prostate biopsies secured, processed, and independently diagnosed at an unrelated institution, we used Paige Prostate to review 1876 prostate core biopsy whole-slide images (WSIs) from our practice at Yale Medicine. Paige Prostate categorizations were compared to the pathology diagnosis originally rendered on the glass slides for each core biopsy. Discrepancies between the rendered diagnosis and categorization by Paige Prostate were each manually reviewed by pathologists with specialized genitourinary pathology expertise. Paige Prostate showed a sensitivity of 97.7% and positive predictive value of 97.9%, and a specificity of 99.3% and negative predictive value of 99.2% in identifying core biopsies with cancer in a data set derived from an independent institution. Areas for improvement were identified in Paige Prostate's handling of poor quality scans. Overall, these results demonstrate the feasibility of porting a machine-learning algorithm to an institution remote from its training set, and highlight the potential of such algorithms as a powerful workflow tool for the evaluation of prostate core biopsies in surgical pathology practices.


Asunto(s)
Adenocarcinoma/diagnóstico , Inteligencia Artificial , Interpretación de Imagen Asistida por Computador/métodos , Patología Quirúrgica/métodos , Neoplasias de la Próstata/diagnóstico , Anciano , Anciano de 80 o más Años , Biopsia con Aguja Gruesa , Humanos , Masculino , Persona de Mediana Edad , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...